Review Article
Volume 3 Issue 2 - 2019
Methods of Hip Abductor Muscles Evaluation after Nailing of
Proximal Femoral Fractures (PFF): A Short Review
Ahmed M Ahmed1, Ahmed A Khalifa*
1Resident of orthopedic and traumatology, Qena faculty of medicine and its university hospital, South Valley University 83523, Qena, Egypt.

2Assistant Professor and Consultant of orthopedic and traumatology, Qena faculty of medicine and its university hospital, South Valley University 83523, Qena, Egypt.
*Corresponding Author: Ahmed A. Khalifa MD, FRCS (Tr & Ortho), MSc. Assistant Professor and Consultant of orthopedic and traumatology, Qena faculty of medicine and its university hospital, Qena, Egypt.
Received: October 14, 2019; Published: November 21, 2019
Abstract
Proximal femoral fractures representing a challenge for orthopaedic surgeons, as most of these fractures occur in elderly osteoporotic patients. Various methods of management had been reported, recently, cephalomedullary nailing (CMN) become the most popular method for management of such fractures. Although being highly successful, CMN still have some drawbacks such as persistent hip abductor weakness. In this short review, different methods of hip abductor muscles assessment were discussed.
Keywords: Hip abductor; evaluation; nailing; femoral fractures
Introduction
Proximal femoral fractures (PFF) are frequently seen in daily ortho¬paedic practice, most commonly in elderly patients. [1] Globally there are already more than 1.3 million hip fractures each year [2] which is expected to increase to 6 million annually by the year 2050. [3]
Different techniques for management of such fractures had been reported in the literature, but the use of cephalomedullary nails (CMN) for treating such fractures has gained enormous popularity since the early 1980s [4-6] because of minimal invasiveness, ease of surgery, and theoretical mechanical advantages, particularly in unstable fractures. [7, 8]
Although CMN carries a high success rate, long term persistent complaints such as residual peri-trochanteric pain, stiffness, limping, limited walking distance, and difficulty with stairs have been reported and still a concern. [9-13]
Studies of elderly adults have demonstrated that strength deficit affecting abductor muscles is extremely large after PFF[14, 15]. Although literature reports this strength and power deficit to be as high as 50% [16-18] postoperative abductor weakness is often overlooked, Patients very often describe a lurch (or limp) in their gait, which is often missed by the surgeon, or the lurch is so mild that it may go unnoticed and becomes apparent only on close observation. [19]
The objective of this short review is to highlight principal methods of hip abductor muscle evaluation after the nailing of PFF.
Applied Anatomy of Hip Abductors:
The proximal attachment of the gluteus medius starts from the anterior superior iliac spine and proceeds along the outer edge of the iliac crest to the posterior superior iliac spine. It inserts as a broad, flattened tendon on the anterosuperior portion of the greater trochanter. [20] The average length of the gluteus medius tendon measures 55.9 mm and the average width measures 16.8 mm. The average surface area of the tendinous insertion on the trochanter measures 935 mm2 (658–1294 mm2). [21]
Evidence from previous anatomic studies suggests the insertion of the gluteus medius tendon does not insert broadly on the greater trochanter, but rather covers the posterior tip and extends laterally and anteriorly. [22-24] The gluteus minimus inserts anteriorly on the greater trochanter, and between these two structures lies the sub-gluteus medius bursa. [22, 25]
Methods of Evaluation:
• MRI
Static MRI is used to document post-operative damage to the adjacent soft tissues around the entry points; edema, hematomas, fluid collections as well as lesions to the abductor muscles can be recorded. [25]
• Isokinetic Muscle Testing
Ansari et al. measured hip abductor apparatus isokinetically on a Cybex 6000© dynamometer for comparison with the uninjured side. [26-28] After an initial 5 min of limbering up, the patients performed five external and internal rotations as forcefully as possible at a fixed speed of 30◦ and 60◦ per second. After a rest, they performed 15 consecutive external and internal rotations at 120◦ per second. To evaluate the endurance, values of the first five sets of movements were compared with the last five during a 120◦ per second test speed: Endurance ratio= last five (Nm)/first five (Nm). Peak torque values (Nm) in the injured limb were compared with the values obtained at the contralateral side and the difference was expressed as a percentage of the uninjured side. The percentage was considered to be negative when the peak torque was lower at the fractured side. [27, 28] In the literature, the reliability coefficient of isokinetic Cybex measurements varies between 0.80 and 0.99.[29, 30]
Helmy., et al. measured quantitative isokinetic muscle strength using the KinCom󠇣® dynamometer (KinCom, Chattanooga Groups, Inc, Hixson, Tennessee).[31] A consistent configuration of straps, bolsters, and clamps was used to isolate the testing to the joint of interest. Each KinCom testing session began with a warmup and practice period. Patients were then preloaded to 80% of their maximal force to ensure optimal recruitment of motor units. The peak isokinetic torque was computed from the average of 3 repetitions. The hip abductors were tested bilaterally. They included testing of the knee extensors to determine whether antegrade nailing affected only muscles around the hip or produced a more global functional deficit within the limb.[32]
Ivanova., et al. measured the isometric strength of leg muscles 1 week and 6 months post-fracture with hand-held dynamometer Lafayette (USA), whereas the fractured leg was tested first. During the trials, the subjects sat on a chair. For measuring hip abduction, the hip and knee were flexed at 90◦. The dynamometer pad was held at the lateral and medial femoral condyle respectively. The participants were asked to perform a maximal voluntary isometric contraction. Three trials were performed and the best trial was used for further analysis. Hip muscle weakness was quantified by comparing maximal voluntary isometric strength outcome between the fractured and nonfractured leg. [2]
• Manual Muscle Testing
The Trendelenburg test: patients who can balance using finger sup¬port only are asked to stand on one leg, flexing the other leg at the knee, while keeping the hip in extension. The Trendelenburg sign is investigated by posterior inspection after the identification of appropriate anatomic landmarks. [32] The exam¬iner kneels in front of the patient to observe pelvic tilt. The test is negative when the unsupported pelvis is raised normally while standing on one leg and held there for at least 30 seconds.[27, 28, 33, 34] In terms of hip kinetics, it is manifested as a decreased hip abduction angle and exaggerated lateral trunk lean. [35] The Trendelenburg gait pattern or lateral trunk lean towards the affected extremity is a compensatory mechanism for the weakened hip abductor musculature. Furthermore, the modified McKay criteria are useful to assess if a patient has Trendelenburg gait. These criteria measure pain symptoms, gait pattern, Trendelenburg sign status, and the range of hip joint movement. [19]
The abductor power of the patients is assessed according to the scale proposed by the Medical Research Council (MRC). [34]
• EMG
The muscles are evaluated by the criteria of the American Academy of Electrophysiological Medi¬cine for needle EMG: The vastus media¬lis, gastrocnemius, and extensor hallucis longus muscles are assessed to determine any evidence of spinal-originated problems. In order to exclude patients with polyneu¬ropathy, radiculopathy, or plexopathy, nerve conduction studies of both lower extremities are performed.
Gluteus me¬dius muscles are assessed bilaterally to evaluate the SGN, the vastus medialis muscle for L4 root, extensor hallucis longus muscle for L5 root, and gastrocnemius muscle for S1 root. First, resting activities are assessed for the signs of acute denerva¬tion (fibrillation and positive sharp waves), followed by observa¬tion of the recruitment pattern, the examination of the motor unit action potential (MUAP) amplitudes, and time characteristics. Finally, motor patterns of interferences are investigated dur¬ing muscle contractions to obtain information about denerva¬tion and reinnervation of examined muscles. [27, 28, 34, 36]
• Gait Analysis
Dujardin., et al. reported on the interindividual variations in hip motion during normal gait (gait velocity, stride length, and abduction angle). [37]
Paul., et al. used the Intelligent Device for Energy Expenditure and Gait analysis (IDEEA; MiniSun Inc, Fresno, CA), a portable microcomputer-based device to measure gait, postural movement, and energy expenditure. The device is noninvasive and consists of a small microprocessor clipped to a subject’s belt with 5 sensors secured to the subject’s body. The IDEEA has been previously validated for the evaluation of gait parameters. [38] The IDEEA was applied to all patients at postoperative follow-up visits in the examination room as per the standardized protocol used in the validation trial. Patients were evaluated on a reserved 20-m flat course, and gait parameters were measured. Patients were allowed to use a cane for assistance and balance as needed. Parameters included single limb stance (SLS), cadence, cycle duration, stride length, and pulling acceleration. [39]
Archdeacon., et al. used three-dimensional gait analysis at 2 distinct time points [Time 1 = independent ambulation without ambulatory aide, 2.0 (60.6) months; Time 2 = approximately 6 months after injury with clinical and radiographic fracture healing, 7.2 (61.5) months] using a 3D-motion analysis system (Motion Analysis Corporation, Santa Rosa, CA) with 2 force plates (AMTI, Watertown, MA). The study subjects were instrumented with reflective markers using a modified Helen Hayes marker set with the static trial. [40] The video was collected at 240 Hz and time-synchronized with the force plates collected at 1200 Hz. Subjects were instructed to ambulate at a self-selected walking speed. Temporal-spatial, kinematic, and kinetic data were collected and normalized to 100% of the gait cycle, and kinetic data were also normalized to body mass (Nm/kg) (Visual 3D; C-Motion Inc. Rockville, MD). Temporal-spatial parameters included gait velocity (m/s), stride length (cm), and stride width. Hip and trunk kinematics included hip adduction angle◦ and lateral trunk lean◦. Hip kinetics included hip abductor moment (Nm/kg). [35]
Helmy., et al. collected motion data with an 8 Eagle camera Motion Analysis (Santa Rosa, California) real-time system using EvaRT 4.1 software. Analog data that were collected simultaneously include Force (or Kinetic) data via 2 AMTI (Amherst, Massachusetts) force platforms (OR 6-5) mounted in the center of the motion capture volume and their amplifiers (SGA6-4) and 16 channels of telemetered electromyography (EMG) using two Noraxon Telymyo systems. A modified Helen Hayes marker set that consisted of 30 retro-reflective markers for the static trial and 26 markers for the dynamic (walking) trials were affixed over key anatomic landmarks. This marker set is a full-body marker set that includes arms and trunk motion. Motion data were collected at 60 Hz. Force and electromyography (EMG) data were collected via an A/D interface board at a rate of 1200 Hz and were time matched to the motion data by EvaRT. Motion data were filtered in EvaRT at 6 Hz and then saved for postprocessing. Postprocessing of the motion and force data was done in Orthotrak 6.0 (Motion Analysis Corp, Santa Rosa, California). Orthotrak calculates temporal-spatial characteristics. Temporal spatial data included single-leg support time and step length, whereas kinetic and kinematic data included hip abductor movement and pelvic obliquity. Joint angles, joint forces, and internal joint moments were also calculated. [32]
References
  1. B.Gullberg., et al. “Incidence of hip fractures in Malmö, Sweden (1950–1991)”. Bone 14 (1993): 23-29
  2. Natalja Ivanova., et al. “Changes in hip muscle strength after proximal femoral fracture in elderly women”. Acta Kinesiologiae Universitatis Tartuensis 17 (2011): 80-8.
  3. Kannus P., et al. “Epidemiology of hip fractures”. Bone 18 (1996): 57S-63S.
  4. PT C. “The gamma nail - a significant advance or a passion fashion?” The Journal of bone and joint surgery. British volume 74 (1992): 329-31.
  5. Gupta RK., et al. “Unstable trochanteric fractures: the role of lateral wall reconstruction”. International Orthopaedics 34.1 (2010): 125-129.
  6. Schipper IB., et al. “Treatment of unstable trochanteric fractures. Randomised comparison of the gamma nail and the proximal femoral nail”. The Journal of bone and joint surgery. British volume 86.1 (2004): 86-94.
  7. Anglen JO., et al. “Nail or plate fixation of intertrochanteric hip fractures: changing pattern of practice. A review of the American Board of Orthopaedic Surgery Database”. The Journal of bone and joint surgery. American volume 90.4 (2008): 700-107.
  8. Bhandari M., et al. “Gamma nails revisited: gamma nails versus compression hip screws in the management of intertrochanteric fractures of the hip: a meta-analysis”. Journal of Orthopaedic Trauma 23.6 (2009): 460-464.
  9. Bain GI., et al. “Abduction strength following intramedullary nailing of the femur”. Journal of Orthopaedic Trauma 11.2 (1997): 93-97.
  10. Bednar DA and Ali P. “Intramedullary nailing of femoral shaft fractures: reoperation and return to work”. Canadian Journal of Surgery 36.5 (1993): 464-466.
  11. Dodenhoff RM., et al. “Proximal thigh pain after femoral nailing. Causes and treatment”. The Journal of bone and joint surgery. British volume 79.5 (1997): 738-741.
  12. Biyani A., et al. “Assessment of hip abductor function in relation to peritrochanteric heterotopic ossification after closed femoral nailing”. Injury 24.2 (1993): 97-100.
  13. Paterno MV., et al. “Early rehabilitation following surgical fixation of a femoral shaft fracture”. Physical Therapy 86.4 (2006): 558-572.
  14. Portegijs E., et al. “Leg extension power deficit and mobility limitation in women recovering from hip fracture”. American Journal of Physical Medicine & Rehabilitation 87.5 (2008): 363-370.
  15. Sherrington C., et al. “Physical exercise after hip fracture: an evidence overview”. European Journal of Physical and Rehabilitation Medicine 47.2 (2011): 297-307.
  16. Mitchell SL., et al. “Randomized controlled trial of quadriceps training after proximal femoral fracture”. Clinical Rehabilitation 15.3 (2001): 282-290.
  17. Roy MA and Doherty TJ. “Reliability of hand-held dynamometry in assessment of knee extensor strength after hip fracture”. American Journal of Physical Medicine & Rehabilitation 83.11 (2004): 813-818.
  18. Sherrington C., et al. “A randomised trial of weight-bearing versus non-weight-bearing exercise for improving physical ability in inpatients after hip fracture”. Australian Journal of Physiotherapy 49.1 (2003): 15-22.
  19. Nitin Wale., et al. “Abductor weakness in intertrochantric fractures operated with PFN and its management”. Indian Journal of Orthopaedics Surgery 4.3 (2018): 230-233.
  20. Gottschalk F., et al. “The functional anatomy of tensor fasciae latae and gluteus medius and minimus”. Journal of Anatomy 166 (1989): 179-189.
  21. McConnell T., et al. “Gluteus medius tendon injury during reaming for gamma nail insertion”. Clinical Orthopaedics and Related Research 407 (2003): 199-202.
  22. Heimkes B., et al. “The transgluteal approaches to the hip”. Archives of Orthopaedic and Trauma Surgery 111.4 (1992): 220-223.
  23. Nazarian S., et al. “Anatomic basis of the transgluteal approach to the hip”. Surgical and Radiologic Anatomy 9.1 (1987): 27-35.
  24. Robertson WJ., et al. “Anatomy and dimensions of the gluteus medius tendon insertion”. Arthroscopy 24.2 (2008): 130-136.
  25. Pfirrmann CW., et al. “Greater trochanter of the hip: attachment of the abductor mechanism and a complex of three bursae--MR imaging and MR bursography in cadavers and MR imaging in asymptomatic volunteers”. Radiology 221.2 (2001): 469-477.
  26. Markhede G and Grimby G. “Measurement of strength of hip joint muscles”. Scandinavian Journal of Rehabilitation Medicine 12.4 (1980): 169-174.
  27. Ansari Moein CM., et al. “Intramedullary femoral nailing through the trochanteric fossa versus greater trochanter tip: a randomized controlled study with in-depth functional outcome results”. European Journal of Trauma and Emergency Surgery 37.6 (2011): 615-622.
  28. Ansari Moein C., et al. “Functional outcome after antegrade femoral nailing: a comparison of trochanteric fossa versus tip of greater trochanter entry point”. Journal of Orthopaedic Trauma 25.4 (2011): 196-201.
  29. Burnett CN., et al. “Reliability of isokinetic measurements of hip muscle torque in young boys”. Physical Therapy 70.4 (1990): 244-249.
  30. Emery CA., et al. “Test-retest reliabilty of isokinetic hip adductor and flexor muscle strength”. Clinical Journal of Sport Medicine 9.2 (1999): 79-85.
  31. Borrelli J Jr., et al. “Functional outcome after isolated acetabular fractures”. Journal of Orthopaedic Trauma 162 (2002): 73-81.
  32. Helmy N., et al. “Muscle function and functional outcome following standard antegrade reamed intramedullary nailing of isolated femoral shaft fractures”. Journal of Orthopaedic Trauma 22.1 (2008): 10-15.
  33. Hardcastle P and Nade S. “The significance of the Trendelenburg test”. The Journal of bone and joint surgery. British volume 67.5 (1985): 741-746.
  34. Mehmet Mesut Sonmez., et al. “Evaluation of the Superior Gluteal Nerve During Proximal Femoral Nailing”. Journal of Clinical and Analytical Medicine 8.3 (2017): 226-229.
  35. Archdeacon M., et al. “A prospective functional outcome and motion analysis evaluation of the hip abductors after femur fracture and antegrade nailing”. Journal of Orthopaedic Trauma 22.1 (2008): 3-9.
  36. Shin J. Oh. “Clinical Electromyography. Nerve conduction studies”. Philadelphia: Lippincott Williams & Wilkins 3rd edition (2003): p 409-16.
  37. F.H.Dujardin., et al. “Interindividual variations of the hip joint motion in normal gait”. Gait Posture 5 (1997): 246-250.
  38. Gardner MJ., et al. “An evaluation of accuracy and repeatability of a novel gait analysis device”. Archives of Orthopaedic and Trauma Surgery 127.3 (2007): 223-227.
  39. Paul O., et al. “Functional and radiographic outcomes of intertrochanteric hip fractures treated with calcar reduction, compression, and trochanteric entry nailing”. Journal of Orthopaedic Trauma 26.3 (2012): 148-154.
  40. J P. Motion analysis. “Gait analysis: Normal and pathological function”. Thorofare NJ: Slack (1992).
Citation: Ahmed M Ahmed and Ahmed A Khalifa. “Methods of Hip Abductor Muscles Evaluation after Nailing of Proximal Femoral Fractures (PFF): A Short Review”. Orthopaedic Surgery and Traumatology 3.2 (2019): 22-26.
Copyright: © 2019 Ahmed M Ahmed and Ahmed A Khalifa. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.